<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>3013</ErrorNumber>
<ErrorFamily>Workstation Communications</ErrorFamily>
<ErrorMessage>
WSCOMM: Unable to process Abort
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Platesetter_3244</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The recorder is unable to reject the plate because it has already been sent to
the processor.  It will not be marked "reject" and must be found in the stack of
processed plates.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
The workstation tried to mark a plate as reject, but the platesetter was unable
to.  This plate must be found in the stack of processed plates.
</text></DescriptionText>
</OperatorAction>
<Cause>
The plate could not be aborted because it had already entered the processor.
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>